To Develop Simulations of Steel Roof Truss and Analysis of Impact of Different Input Parameters in Ansys
Keywords:
Steel Trusses, Steel Structure, Optimisation, Architectural Effectiveness, PurlinsAbstract
A truss is an unchangeable shape made up of many members linked at their ends in metallic structures. Roof trusses are a common component of commercial structures such as auditoriums, workplaces, garages, and warehousing. Roof trusses are used to support roof inanimate masses, living masses, and bending stress caused by wind and disaster. In this study, Howe and Pratt's truss are used to achieve extraordinary spans and eave heights. Four specific spans of 5m, 10m, 15m, and 20m have been included, with eave heights of 5m, 10m, 15m, and 20m, respectively. The use of the STAAD pro software program and layout for various structural variables such as Purlins has been completed.
Downloads
References
. Anushlimbage (2016) - “ Analysis of steel roof Type truss for four different spans” IJLTET Vol.6 Issue 4 March 2016 [2]. A.S.Gawande, Mr. S. A. Chauhan (2018) - “Design of Industrial Steel Building by Limit State Method”
. Tejas D. Parekh, DishaParmar, Yati tank (2017) - “Analysis of Howe Roof Truss using Different Rise and Span” International Journal of Engineering Trends and Technology (IJETT) – Volume 47 Number 3 May 2017]
. Dinesh Kumar Gupta Mirza AamirBaig (2017) - “Design of Industrial Steel Building by Limit State Method” International Journal of Advanced Research, Ideas, and Innovations in Technology. (Volume3, Issue4) 2017
. Yash Patel Yashveersinh Chhasatia (2016) - “Analysis and design of conventional industrial roof truss and compare it with tubular industrial roof truss” IJSTE - the international journal of science technology & engineering volume 2 Issue 10 April 2016
. Manoj Nallanathe, Ramesh Bhaskar, Kishore (2018) - “ Efficiency study of different steel truss using (staad. pro)” Volume 119 No. 17 2018, 3095-3101
. AnishaGoswami, Dr. TusharShende (2018)- “PreEngineered Building Design of an Industrial Warehouse” International research journal of engineering and technology (irjet) Volume: 05 issues: 06, June 2018
. Duggal S.K, “Limit State Design of Steel Structural” Tata McGraw Hill education private limited, New Delhi, (2010). ]IS: 875 (Part 1) – 1987 Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures (Dead Load)
. [IS: 875 (Part 2) – 1987 Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures (Imposed Load)
. IS: 875 (Part 3) – 1987 Code of Practice for Design Loads (Other than Earthquake) for Buildings And Structures (Wind Load)
. IS 800 – 2007 Indian Standard General Construction in Steel – Code of Practice.
. Kankuntla Ashok Y.Kankuntla Ashok Y., NirantarShalaka R., Rajgiri Dinesh,” Optimum Design of an Industrial WareHouse”, International Journal of Science and Research (IJSR), Volume 6 Issue 6, June 2017, pp 25622566
. Hultman Max, 2010. Weight optimization of steel trusses by a genetic algorithm. [ONLINE] Availablehttp://www.kstr.lth.se/fileadmin/kstr/pdf_files/Exj obb/TVBK-5000_pdf/TVBK-5176MH.pdf.
. Baker. W.F., 2012. Maxwell’s reciprocal diagrams and discrete Michell frames. [ONLINE] Available at:https://architecture.mit.edu/sites/architecture.mit.edu/files/ attachments/lecture/MaxwellReciprocalDiagra
mandDiscreteMichellFrames.pdf.
. Prajot A. Kakde & Ravindra Desai, “Comparative study of Outrigger and belt truss structural system for steel and fixed point material”, International Journal of Engineering and Technology, eISSN: 2395-0056, pISSN:2395-0072, Volume: 04, Issue:05, Page 142-147, 2017
. ChetanJaiprakashChitte, " Analysis and Design of Pratt Truss by IS: 800: 2007, & IS: 800: 1984, IJCEM International Journal of Computational Engineering & Management, Vol. 21 Issue 2, March 2018.