Power Quality Improvement by Using Phase Shifting Transformer

Authors

  • Rouf Shafi M. Tech Scholar, Department Electrical Engineering, RIMT University, Mandi Gobingarh , Punjab, India Author
  • Dharminder Kumar Assistant Professor, Department. of Electrical Engineering, RIMT University, Mandi Gobingarh, Punjab, India Author

Keywords:

Phase Shifting, Multipurpose Converters, Power Quality, Harmonic Mitigation, Line Current Distortion

Abstract

Non-linear loads like direct current  loads and induction motor drives are a major source of  harmonics in the power system. Multipulse converters are widely used to overcome the problem of harmonics.  This thesis highlights the performance comparison of  different multipulse converters which are simulated in  MATLAB/SIMULINK. Performance comparison of the  6-pulse, 12-pulse, 24-pulse and 48-pulse converters  feeding RL-load is performed. The phase shift in the  converters is achieved by using ziz-zag phase shifting  transformers. The Total Harmonic Distortion (THD) in  input current and input voltage along with ripple content  in the output voltage and output current are measured  and their corresponding waveforms are observed. Also,  performance comparison of 6-pulse, 12-pulse, 24-pulse  and 48-pulse converters is performed. The results  obtained with a multipulse converter are compared with  those obtained with the six pulse converter. It is  observed that multipulse converters provide better  results in terms of THD in input voltage and input  current. It is found that as the pulse number of a  converter increases, THD in input voltage and input  current along with ripple content in the output voltage  and output current is decreased. 

Downloads

Download data is not yet available.

References

Bin Wu “High Power Converters and AC Drives” 2006 Ed. A John Wiley & Sons, Inc., Publication.

Muhammad H. Rashid, “Power electronics: Circuits, devices and applications” 3rd Ed. Oxford, UK: Elsevier Inc., 2011. [3] Jil McIntosh, “How it works: Electric vehicle charging”, driving .ca, Oct 27, 2017

Kotubdin, Andrew D Moore, Anup Barai, James Marco, “Effects of high frequency current ripple on vehicle battery performance”, Science Direct ,Applied Energy, vol. 178, Sep 15, 2016, pages 142-154.

Gang Zhao, Yunfie Yue, “Harmonic analysis and suppression of electrical vehicle charging station”, Proceedings of 2017IEEE International Conference on Mechatronics and Automation (ICMA), Aug 6-9, 2017, Takamatsu, Japan.

Wajahat Khan, Furkan Ahmad, Mohammad Saad Alam (AMU), “ Fast EV charging station integration with grid ensuring optimal and quality power exchange”, Science Direct, Aug 16, 2018.

D. A. Paice, “Transformers for Multipulse AC/DC Converters,” U.S. Patent 6 101 113, Aug. 8, 2000. [8] D. A. Paice, Power Electronic Converter Harmonics: Multipulse Methods for Clean Power. New York: IEEE Press, 1996.

S. Hansen, U. Borup, and F. Blaabjerg, “Quasi 12-pulse rectifier for adjustable speed drives,” in Proc. 2001 IEEE APEC1 Conf., vol. 2, Mar. 4–8, 2001, pp. 806–812.

Bhim Singh, Senior Member, IEEE, G. Bhuvaneswari, Senior Member, IEEE, Vipin Garg, Member, IEEE, and Sanjay Gairola, “Pulse Multiplication in AC–DC Converters for Harmonic Mitigation in Vector-Controlled Induction Motor Drives”, IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 21, NO. 2, JUNE 2006

Downloads

Published

2022-04-30

How to Cite