The Functioning of a Voltage Transformer In Relation To Power Quality
Keywords:
Conductive Disturbances, Electric Energy, Power Quality, Voltage TransformerAbstract
Conductive expansions in the giving voltage might affect the root mean square voltage and the situation with the voltage twist on the mains, bringing about power quality debasement. The motivation behind this exploration is to give the aftereffects of examination focus assessments into the exchange of conductive disagreeable impacts from the required side of a voltage transformer to the discretionary side, as well as the other way around. By the voltage transformer's store bringing down with predictable evaluation of the disrupting impact signal, the parts of specific symphonious trade and the component of hard and fast consonant distortion in the voltage on the assistant side of the endeavored voltage transformer are unaffected. The parts of explicit symphonious trade and the component of total symphonious mutilation in the voltage on the assistant side of the attempted voltage transformer increment as the reserve voltage of the attempted voltage transformer increments with consistent sufficiency and repeat of disrupting impact signal.
Downloads
References
I. Sengupta, A. Kumar, and R. Kumar Dwivedi, “Study of SigmoidSpectral Composite Kernel based noise classifier with entropy in handling non linear separation of classes,” 2018, doi: 10.1109/UPCON.2018.8596985.
T. K. Pathak, R. E. Kroon, and H. C. Swart, “Photocatalytic and biological applications of Ag and Au doped ZnO nanomaterial synthesized by
combustion,” Vacuum, 2018, doi: 10.1016/j.vacuum.2018.09.020.
N. Agarwal, N. Agarwal, and M. K. Sharma, “Design a test chip to find out mixed signal interference with broad range instrumentation amplifier,” 2016, doi: 10.1109/ISNE.2016.7543366.
D. P. J. Young, W. P. Erickson, R. E. Good, M. D. Strickland, and G. D. Johnson, “Avian and Bat Mortality Associated with the Initial Phase of the Foote Creek Rim Windpower Project, Carbon County, Wyoming, November 1998-June 2002: Final Report.,” West. Ecosyst. Technol. Inc, 2003.
L. P. Cornell and D. M. Klarer, “Patterns of dissolved oxygen, productivity and respiration in Old Woman Creek estuary, Erie county, ohio during low and high water conditions,” Ohio J. Sci., 2008.
P. Bhardwaj, D. V. Rai, M. L. Garg, and B. P. Mohanty, “Potential of electrical impedance spectroscopy to differentiate between healthy and osteopenic bone,” Clin. Biomech., 2018, doi: 10.1016/j.clinbiomech.2018.05.014.
R. Kaur, K. Goyal, D. V. Rai, and S. K. Tripathi, “Study of electrical properties of Ag/Rudraksha/Ag device,” 2021, doi: 10.1063/5.0052494.
J. Saji et al., “Polyvinyl Alcohol Scaffold Incorporated with Silver Nanoparticles and Titanium Dioxide: Electrical, Dielectric, Dye Degradation, and Antibacterial Properties,” 2021, doi: 10.1007/978- 981-16-0942-8_36.
S. D. Verifier and A. H. Drive, “Simulink ® Verification and Validation TM Reference,” ReVision, 2015.
M. Bobaru, M. Borges, M. d’Amorim, and C. S. Păsăreanu, NASA formal methods : third international symposium, NFM 2011, Pasadena, CA, USA, April 18-20, 2011 : proceedings. 2011.
S. Committee, IEEE Standard for Software Verification and Validation IEEE Standard for Software Verification and Validation. 1998.
J. H. Liu, W. S. Zhu, S. C. Li, and F. Y. Yang, “Analysis of rheological characteristics and stability of surrounding rock masses of Xiaolangdi Hydrojunction underground caverns by using FLAC3D,” Yanshilixue Yu Gongcheng Xuebao/Chinese J. Rock Mech. Eng., 2005.
M. Kaczmarek and D. Brodecki, “Transformation of transient overvoltages by inductive voltage transformers,” Sensors, 2021, doi: 10.3390/s21124167.
A. Heidary, K. Rouzbehi, H. Radmanesh, and J. Pou, “Voltage Transformer Ferroresonance: An Inhibitor Device,” IEEE Trans. Power Deliv., 2020, doi: 10.1109/TPWRD.2020.3005321.
E. Lesniewska, M. Kaczmarek, and E. Stano, “3D Electromagnetic Field Analysis Applied to Evaluate the Accuracy of a Voltage Transformer under Distorted Voltage,” Energies, 2021, doi: 10.3390/en14010136.
[16]D. Saveliev, D. Chashin, L. Fetisov, M. Shamonin, and Y. Fetisov, “Ceramic-heterostructure based magnetoelectric voltage transformer with an adjustable transformation ratio,” Materials (Basel)., 2020, doi: 10.3390/ma13183981.
O. Tsukamoto and S. Akita, “Overview of R&D activities on applications of superconductivity to power apparatuses in Japan,” 2002, doi: 10.1016/S0011-2275(02)00054-1.
J. E. Mendonca, S. Carlos, H. S. Mattos, and J. H. Rittershaussen, “First deepwater installation of a subsea ESP: RJS-477A, Campos Basin, Brazil,” Proc. Annu. Offshore Technol. Conf., 1999, doi: 10.4043/10969-ms.
L. Tóth and T. Tóth, “Short-circuit test on power transformers with pressure measurement,” 1999, doi: 10.1109/PTC.1999.826578.
M. Faifer, C. Laurano, R. Ottoboni, S. Toscani, and M. Zanoni, “Harmonic Distortion Compensation in Voltage Transformers for Improved Power Quality Measurements,” IEEE Trans. Instrum. Meas., 2019, doi: 10.1109/TIM.2019.2906990.
G. Crotti, D. Giordano, G. D’Avanzo, P. S. Letizia, and M. Luiso, “A New Industry-Oriented Technique for the Wideband Characterization of Voltage Transformers,” Meas. J. Int. Meas. Confed., 2021, doi: 10.1016/j.measurement.2021.109674.
Z. Li, Y. Zheng, A. Abu-Siada, M. Lu, H. Li, and Y. Xu, “Online evaluation for the accuracy of electronic voltage transformer based on recursive principal components analysis,” Energies, 2020, doi: 10.3390/en13215576.
N. A. Akashah et al., “A review: Partial discharge detection using acoustic sensor on high voltage transformer,” 2020, doi: 10.1088/1742- 6596/1432/1/012004.
T. Lei, M. Faifer, R. Ottoboni, and S. Toscani, “On line fault detection technique for voltage transformers,” Meas. J. Int. Meas. Confed., 2017, doi: 10.1016/j.measurement.2017.03.002.
R. Haensel, “Status of the ESRF at the end of 1990,” Nucl. Inst. Methods Phys. Res. A, 1991, doi: 10.1016/0168-9002(91)90278-X.