Separating FECG from MECG and Analyzing Fetal Heart Rate

Authors

  • Farhad Ahmad Mir M.Tech. Student, Department of Electronics and Communication Engineering, RIMT University, Punjab, India Author
  • Monika Mehra Associate Professor, Department of Electronics and Communication Engineering, RIMT University, Punjab, India Author

DOI:

https://doi.org/10.55524/

Keywords:

FECG, MECG, Heart rate, fetal coronary heart

Abstract

Figuring out fetal coronary heart can be  essential for monitoring the situation of a fetus. While an  ECG signal is recorded by way of putting electrodes on the  maternal stomach, the fetal ECG is regularly masked by  using the maternal ECG sign and noise. Via using an LMS  adaptive filter to extract the fetal ECG signal, after which  the use of the Pan & Tompkins algorithm to hit upon the  QRS complexes, the fetal heart may be determined with  very low errors. 

Downloads

Download data is not yet available.

References

M. Ghodsi, H. Hassani, and S. Sanei, “Extracting fetal heart signal from noisy maternal ECG by multivariate singular spectrum analysis,” Statistics and Its Interface, vol. 3, pp. 399-411. 2010.

N. Marchon and G. Naik, "QRS detector for maternal abdominal ECG," 2016 International Conference on Signal and Information Processing (IConSIP), Vishnupuri, 2016, pp.

S. Abboud, A. Alaluf, S. Einav, D. Sadeh, “Real-Time Abdominal Fetal ECG Recording Using a Hardware Correlator,” .

V. Vigneron, A. Paraschiv-Ionescu, A. Azancot, O. Sibony and C. Jutten, "Fetal electrocardiogram extraction based on non-stationary ICA and wavelet denoising," Seventh International Symposium on Signal Processing and Its Applications, 2003. Proceedings., 2003.

J. Szalai and F. E. Mozes, "Determining fetal heart rate using independent component analysis," 2014 IEEE 10th International Conference on Intelligent Computer Communication and Processing (ICCP).

J. Pan and W. J. Tompkins, "A Real-Time QRS Detection Algorithm," in IEEE Transactions on Biomedical Engineering, vol. BME-32, no. 3, pp. 230-236, March 1985.

B. Paul and P. Mythili, "ECG noise removal using GA tuned sign-data least mean square algorithm," 2012 IEEE International Conference on Advanced Communication Control and Computing Technologies (ICACCCT), Ramanathapuram, 2012, pp. 100-103. doi: 10.1109/ICACCCT.2012.6320750

Ni.com. (2017). Least Mean Square (LMS) Adaptive Filter -National Instruments. [online] Available at: http://www.ni.com/example/31220/en/ [Accessed 16 Dec. 2017].

M. Wasimuddin and N. Gupta, "Design and implementation of Least Mean Square adaptive filter on fetal electrocardiography," Proceedings of the 2014 Zone 1 Conference of the American Society for Engineering Education, Bridgeport, CT, 2014, pp. 1-5. doi: 10.1109/ASEEZone1.2014.6820650

Downloads

Published

2022-01-30

How to Cite

Separating FECG from MECG and Analyzing Fetal Heart Rate . (2022). International Journal of Innovative Research in Computer Science & Technology, 10(1), 27–30. https://doi.org/10.55524/